LadonX™ Data Cable Category 7A&7

Hermesys LadonX™ Data Cable series Cat. 7A and Cat. 7 S/FTP LSOH data cable is well suited for 10 Gigabit Ethernet Cabling System and installations in fire safety environments.
Bandwidth frequency up to 1000Mhz for Cat. 7A and 600Mhz for Cat. 7. Supercharge and future-proof your network infrastructures for bandwidth hungry applications.
Superior design of overall tinned copper braiding and individual pair shielding provides excellent electromagnetic/radio frequency interference (EMI/RFI) protection and alien crosstalk suppression.

Features and Benefits

  • Each single pair individually shielded with Aluminum foil and overall with tinned copper braiding.
  • Available for Power Over Ethernet (POE), POE +
  • Data cable for structured premises cabling, digital/analogue voice, video and data signals.
  • RoHS Compliant.

Reference Standard

  • ANSI/TIA 568-C.2
  • ISO/IEC 11801
  • UL444
  • EN 50173
  • IEC 61156-5
  • IEC 60332-1 & -2
  • IEC 60754-1 & -2
  • IEC 61034-1 & -2

Category 7A & Category 7
Conductor Material Annealed Bare Copper Conductor Size 23 AWG
Cold Bend Test -20˚C x 4hrs No Crack Jacket Type LSOH (PE optional)
Insulation Material Foam PE Cross Filler N/A
Pair 1 Blue / White – Blue Pair 2 Orange / White – Orange
Pair 3 Green / White – Green Pair 4 Brown / White – Brown
Drain Wire 0.45mm Tinned copper Single Pair Shielding Al-mylar foil
Overall Shielding 1 Tinned copper braiding Overall Shielding 2 N/A
Max Pulling Tension (N) ≤ 100 N Dielectric Strength AC 1.5 KV / 2sec
Min. Bending Radius (mm) ≥ 8 times of overall diameter Conductor Resistance (Ω/100m @ 20˚C) Max. 9.50
Operating Temperature -20 ˚C to +60 ˚C Installation Temperature 0 ˚C to +50 ˚C
DC Resistance Unbalance (%) Max. 2.0 Velocity of Propagation (%) 74%
Pair-to-ground Capacitance Unbalance (pF/100m) Max. 330 Input Impedance (ohm) 100 ± 15Ω (1MHz – 100MHz)

100 ± 18Ω (101MHz – 250MHz)

100 ± 25Ω (251MHz – 1000MHz)

 

IEC 61156-5 ed 2.0 Category 7a Horizontal Cable Parameters                                                                                              AT 20ºC
Frequency (MHz) 4 8 10 16 20 25 31.25 62.5 100 200 250 300 500 600 800 1000
Ins. Loss

(dB/100m)

3.7 5.2 5.8 7.3 8.2 9.2 10.3 14.6 18.5 26.5 29.7 32.7 42.8 47.1 54.9 61.9
RL

(dB) Min

23 24.5 25 25 25 24.3 23.6 21.5 20.1 18.0 17.3 17.3 17.3 17.3 16.1 15.1
NEXT

(dB/100m)

78 78 78 78 78 78 78 78 75.4 70.9 69.4 68.2 64.9 63.7 61.9 60.4
ELFEXT

(dB/100m)

78 77.2 75.3 71.2 69.3 67.3 65.4 59.4 55.3 49.3 47.3 45.8 41.3 39.7 37.2 35.3
PS-NEXT

(dB/100m)

75 75 75 75 75 75 75 75 72.4 67.9 66.4 65.2 61.9 60.7 58.9 57.4
PS-ELFEXT

(dB/100m) Min

75 74.2 72.3 68.2 66.3 64.3 62.4 56.4 52.3 46.3 44.3 42.8 38.3 36.7 34.2 32.3
Delay Skew 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45
Po. Delay

(ns/100) Min

552 547 545 543 542 541 540 539 538 537 536 536 536 535 535 535

 

IEC 61156-5 ed 2.0 Category 7 Horizontal Cable Parameters                                                                                 AT 20ºC
Frequency (MHz) 4 8 10 16 20 25 31.25 62.5 100 200 250 300 500 600
Ins. Loss

(dB/100m)

3.7 5.2 5.9 7.4 8.3 9.3 10.4 14.9 19.0 27.5 31.0 34.2 45.3 50.1
RL

(dB) Min

23 24.5 25 25 25 24.3 23.6 21.5 20.1 18.0 17.3 17.3 17.3 17.3
NEXT

(dB/100m)

78 78 78 78 78 78 78 75.5 72.4 67.9 66.4 65.2 61.9 60.7
ELFEXT

(dB/100m)

78 77.2 75.3 71.2 69.3 67.3 65.4 59.4 55.3 49.3 47.3 45.8 41.3 39.7
PS-NEXT

(dB/100m)

75 75 75 75 75 75 75 72.5 69.4 64.9 63.4 62.2 58.9 57.7
PS-ELFEXT

(dB/100m) Min

75 74.2 72.3 68.2 66.3 64.3 62.4 56.4 52.3 46.3 44.3 42.8 38.3 36.7
Delay Skew 25 25 25 25 25 25 25 25 25 25 25 25 25 25
Po. Delay

(ns/100) Min

552 547 545 543 542 541 540 539 538 537 536 536 536 535