Data Cable Category 6A

Hermesys LadonX™ Data Cable series Cat. 6A U/UTP, F/UTP, S/FTP, U/FTP , F/FTP LSOH data cable is well suited for 10 Gigabit Ethernet Cabling System and installation in fire safety environments. Bandwidth frequency up to 500Mhz.

The cable guarantees the performance of maximum network speed and reliability. The design meets the performance requirments of international standards.

The Hermesys unshielded structured cabling system comprises of unshielded modular connectors, patch panels, patch cords and cables. Shielded structured cabling system comprises of shielded modular connectors, patch panels, patch cords and cables. The system is ideal for deployment in all missioncritical network systems where EMI/RFI might be of a concern.

Superior design of individual pair shielding provide excellent electromagnetic/radio frequency interference (EMI/RFI) protection and alien crosstalk suppression.

Features and Benefits

Smooth, round shape for fast and easy installation.
Available for Power Over Ethernet (POE), POE +
Data cable for structured premises cabling, digital/analogue voice, video and data signals.
RoHS Compliant.

Reference Standard

  • ANSI/TIA 568-C.2
  • ISO/IEC 11801
  • UL444
  • EN 50173
  • IEC 61156-5
  • IEC 60332-1 & -2
  • IEC 60754-1 & -2
  • IEC 61034-1 & -2

Category 6A
Conductor Material Annealed Bare Copper Conductor Size 23 AWG
Cold Bend Test -20˚C x 4hrs No Crack Jacket Type LSOH (PE optional)
Pair 1 Blue / White – Blue Pair 2 Orange / White – Orange
Pair 3 Green / White – Green Pair 4 Brown / White – Brown
Max Pulling Tension (N) ≤ 100 N Dielectric Strength AC 1.5 KV / 2sec
Pair-to-ground Capacitance Unbalance (pF/100m) Max. 330 Input Impedance (ohm) 100 ± 15 Ω ( 1 to 100 MHz);100 ± 22 Ω ( 101 to 250 MHz);100 ± 25 Ω ( 251 to 500 MHz)

 

U/UTP F/UTP U/FTP F/FTP S/FTP
Insulation Material HDPE Foam PE Foam PE Foam PE Foam PE
Drain Wire N/A 0.45mm Tinned copper 0.45mm Tinned copper 0.45mm Tinned copper 0.45mm Tinned copper
Single Pair Shielding N/A N/A Al-mylar foil Al-mylar foil Al-mylar foil
Overall Shielding 1 N/A Al-mylar foil N/A Al-mylar foil TC Braiding
Overall Shielding 2 N/A N/A N/A N/A N/A
Cross Filler PE cross separator PE cross separator N/A N/A N/A
Min. Bending Radius (mm) ≥ 8 times of overall diameter ≥ 8 times of overall diameter ≥ 8 times of overall diameter ≥ 8 times of overall diameter ≥ 8 times of overall diameter
Velocity of Propagation (%) 64% 64% 76% 74% 74%
Installation Temperature 0 ˚C to +50 ˚C 0 ˚C to +50 ˚C 0 ˚C to +50 ˚C 0 ˚C to +50 ˚C 0 ˚C to +50 ˚C
Operating Temperature -20 ˚C to +60 ˚C -20 ˚C to +60 ˚C -20 ˚C to +60 ˚C -20 ˚C to +70 ˚C -20 ˚C to +70 ˚C
Conductor Resistance (Ω/100m @ 20˚C) Max. 9.50 Max. 9.38 Max. 9.38
DC Resistance Unbalance (%) Max. 4.0 Max. 5.0 Max. 2.0
Cable Overall Diameter 7.20 ± 0.3mm 7.30 ± 0.3mm 7.40 ± 0.3 mm 7.40 ± 0.3 mm 7.60 ± 0.4 mm

 

IEC 61156-5 ed 2.0 Category 6a Horizontal Cable Parameters                                                                          AT 20ºC
Frequency (MHz) 1 4 10 16 20 31.25 62.5 100 200 250 500
Ins. Loss

(dB/100m)

2.1 3.8 5.9 7.5 8.4 10.5 15.0 19.1 27.6 31.1 45.3
RL

(dB) Min

20.0 23.0 25.0 25.0 25.0 23.6 21.5 20.1 18.0 17.3 15.2
NEXT

(dB/100m)

74.3 65.3 59.3 56.2 54.8 51.9 47.4 44.3 39.8 38.3 33.8
ELFEXT

(dB/100m)

67.8 55.8 47.8 43.7 41.8 37.9 31.9 27.8 21.8 19.8 13.8
PS-NEXT

(dB/100m)

72.3 63.3 57.3 54.2 52.8 49.9 45.4 42.3 37.8 36.3 31.8
PS-ELFEXT

(dB/100m) Min

64.8 52.8 44.8 40.7 38.8 34.9 28.9 24.8 18.8 16.8 10.8
Delay Skew 45 45 45 45 45 45 45 45 45 45 45
Po. Delay

(ns/100) Min

570.0 552.0 545.4 543.0 542.0 540.4 538.6 537.6 536.5 536.3 535.6