LadonX™ Data Cable Category 5e

Hermesys LadonX™ Data Cable series Cat. 5e U/UTP, F/UTP, SF/UTP 4-pair solid data cable is designed for Gigabit Ethernet and other telecom network protocals. The performance exceeds ANSI/TIA 568-C.2 Category 5e standards.

The Hermesys unshielded structured cabling system comprises of unshielded modular connectors, patch panels, patch cords, and cables.

The Hermesys Shielded structured cabling system comprises of shielded modular connectors, patch panels, patch cords, and cables. The system is ideal for deployment in all missioncritical network systems where EMI/RFI might be of a concern. Added design benefit includes shielding for electromagnetic/radiofrequency interference (EMI/RFI) protection and alien crosstalk suppression.

Features and Benefits

Transmission performance exceeds standard specifications.
Easy pull box ensure proper performance and provide quick installation.
Meets IEEE 802.3af for PoE applications.
Ethernet 10BASE-T, 100BASE-T, 1000BASE-T and 10G BASE-T.
TP-PMD/TP-DDI-ATM 155,622,1200Mbits.
RoHS Compliant.

Reference Standard

  • ANSI/TIA 568-C.2
  • ISO/IEC 11801
  • UL444
  • EN 50173
  • IEC 61156-5
  • IEC 60332-1 & -2 (not suitable for PE jacket)
  • IEC 60754-1 & -2
  • IEC 61034-1 & -2

Category 5e
Conductor Material Annealed Bare Copper Conductor Size 24 AWG
Insulation Material HDPE Jacket Type PVC & LSOH (PE optional)
Pair 1 Blue / White – Blue Pair 2 Orange / White – Orange
Pair 3 Green / White – Green Pair 4 Brown / White – Brown
Cold Bend Test -20˚C x 4hrs No Crack Input Impedance (ohm) 100 ± 15 Ω (1MHz – 100MHz)
Max Pulling Tension (N) ≤ 100 N Dielectric Strength AC 1.5 KV / 2sec
DC Resistance Unbalance (%) Max. 5% Pair-to-ground Capacitance Unbalance (pF/100m) Max. 330 pF/100m

 

U/UTP F/UTP SF/UTP
Insulation Min Thickness 0.18 mm 0.22 mm 0.22 mm
Drain Wire N/A 0.45mm Tinned copper 0.45mm Tinned copper
Single Pair Shielding N/A N/A N/A
Overall Shielding 1 N/A Al-mylar foil Al-mylar foil
Overall Shielding 2 N/A N/A Tinned copper wire braiding(30%)
Cross Filler N/A N/A N/A
Velocity of Propagation (%) 65% 68%
Min. Bending Radius (mm) ≥ 4 times of overall diameter ≥ 8 times of overall diameter ≥ 8 times of overall diameter
Installation Temperature -5 ˚C to +50 ˚C 0 ˚C to +50 ˚C 0 ˚C to +50 ˚C
Operating Temperature -20 ˚C to +75 ˚C -20 ˚C to +60 ˚C -20 ˚C to +60 ˚C
Conductor Resistance (Ω/100m @20˚C) Max. 9.38 Max. 9.50
Insulation Min Tension Strength (psi) Before aging 2400 2320
Insulation Min Elongation (%) Before aging 300 300
Cable Overall Diameter 5.00 ± 0.3mm 6.20 ± 0.3mm 6.8 ± 0.5mm

 

IEC 61156-5 ed 2.0 Category 5e Horizontal Cable Parameters                                                                       AT 20ºC
Frequency (MHz) 1 4 8 10 16 20 25 31.25 62.5 100
Att.

(dB/100m) Max

2.0 4.1 5.8 6.5 8.2 9.3 10.4 11.7 17.0 22.0
RL

(dB) Min

20.0 23.0 24.5 25.0 25.0 25.0 24.3 23.6 21.5 20.1
NEXT

(dB/100m) Min

65.3 56.3 51.8 50.3 47.3 45.8 44.3 42.9 38.4 35.3
ELFEXT

(dB/100m) Min

63.8 51.8 45.7 43.8 39.7 37.8 35.8 33.9 27.9 23.8
PS-NEXT

(dB/100m) Min

62.3 53.3 48.8 47.3 44.3 42.8 41.3 39.9 35.4 32.3
PSELFEXT

(dB/100m) Min

60.8 48.8 42.7 40.8 36.7 34.8 32.8 30.9 24.9 20.8
Delay Skew

(ns/100m) Min

45 45 45 45 45 45 45 45 45 45
Po. Delay

(ns/100) Min

570.0 552.0 546.7 545.4 543.0 542.0 541.2 540.4 538.6 537.6