Hermesys LadonX™ Data Cable series Cat. 5e U/UTP, F/UTP, SF/UTP 4-pair solid data cable is designed for Gigabit Ethernet and other telecom network protocals. The performance exceeds ANSI/TIA 568-C.2 Category 5e standards.
The Hermesys unshielded structured cabling system comprises of unshielded modular connectors, patch panels, patch cords, and cables.
The Hermesys Shielded structured cabling system comprises of shielded modular connectors, patch panels, patch cords, and cables. The system is ideal for deployment in all missioncritical network systems where EMI/RFI might be of a concern. Added design benefit includes shielding for electromagnetic/radiofrequency interference (EMI/RFI) protection and alien crosstalk suppression.
Features and Benefits
Transmission performance exceeds standard specifications.
Easy pull box ensure proper performance and provide quick installation.
Meets IEEE 802.3af for PoE applications.
Ethernet 10BASE-T, 100BASE-T, 1000BASE-T and 10G BASE-T.
TP-PMD/TP-DDI-ATM 155,622,1200Mbits.
RoHS Compliant.
Reference Standard
Category 5e | |||
Conductor Material | Annealed Bare Copper | Conductor Size | 24 AWG |
Insulation Material | HDPE | Jacket Type | PVC & LSOH (PE optional) |
Pair 1 | Blue / White – Blue | Pair 2 | Orange / White – Orange |
Pair 3 | Green / White – Green | Pair 4 | Brown / White – Brown |
Cold Bend Test | -20˚C x 4hrs No Crack | Input Impedance (ohm) | 100 ± 15 Ω (1MHz – 100MHz) |
Max Pulling Tension (N) | ≤ 100 N | Dielectric Strength | AC 1.5 KV / 2sec |
DC Resistance Unbalance (%) | Max. 5% | Pair-to-ground Capacitance Unbalance (pF/100m) | Max. 330 pF/100m |
U/UTP | F/UTP | SF/UTP | |
Insulation Min Thickness | 0.18 mm | 0.22 mm | 0.22 mm |
Drain Wire | N/A | 0.45mm Tinned copper | 0.45mm Tinned copper |
Single Pair Shielding | N/A | N/A | N/A |
Overall Shielding 1 | N/A | Al-mylar foil | Al-mylar foil |
Overall Shielding 2 | N/A | N/A | Tinned copper wire braiding(30%) |
Cross Filler | N/A | N/A | N/A |
Velocity of Propagation (%) | 65% | 68% | |
Min. Bending Radius (mm) | ≥ 4 times of overall diameter | ≥ 8 times of overall diameter | ≥ 8 times of overall diameter |
Installation Temperature | -5 ˚C to +50 ˚C | 0 ˚C to +50 ˚C | 0 ˚C to +50 ˚C |
Operating Temperature | -20 ˚C to +75 ˚C | -20 ˚C to +60 ˚C | -20 ˚C to +60 ˚C |
Conductor Resistance (Ω/100m @20˚C) | Max. 9.38 | Max. 9.50 | |
Insulation Min Tension Strength (psi) Before aging | 2400 | 2320 | |
Insulation Min Elongation (%) Before aging | 300 | 300 | |
Cable Overall Diameter | 5.00 ± 0.3mm | 6.20 ± 0.3mm | 6.8 ± 0.5mm |
IEC 61156-5 ed 2.0 Category 5e Horizontal Cable Parameters AT 20ºC | ||||||||||
Frequency (MHz) | 1 | 4 | 8 | 10 | 16 | 20 | 25 | 31.25 | 62.5 | 100 |
Att.
(dB/100m) Max |
2.0 | 4.1 | 5.8 | 6.5 | 8.2 | 9.3 | 10.4 | 11.7 | 17.0 | 22.0 |
RL
(dB) Min |
20.0 | 23.0 | 24.5 | 25.0 | 25.0 | 25.0 | 24.3 | 23.6 | 21.5 | 20.1 |
NEXT
(dB/100m) Min |
65.3 | 56.3 | 51.8 | 50.3 | 47.3 | 45.8 | 44.3 | 42.9 | 38.4 | 35.3 |
ELFEXT
(dB/100m) Min |
63.8 | 51.8 | 45.7 | 43.8 | 39.7 | 37.8 | 35.8 | 33.9 | 27.9 | 23.8 |
PS-NEXT
(dB/100m) Min |
62.3 | 53.3 | 48.8 | 47.3 | 44.3 | 42.8 | 41.3 | 39.9 | 35.4 | 32.3 |
PSELFEXT
(dB/100m) Min |
60.8 | 48.8 | 42.7 | 40.8 | 36.7 | 34.8 | 32.8 | 30.9 | 24.9 | 20.8 |
Delay Skew
(ns/100m) Min |
45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 |
Po. Delay
(ns/100) Min |
570.0 | 552.0 | 546.7 | 545.4 | 543.0 | 542.0 | 541.2 | 540.4 | 538.6 | 537.6 |