| Number of Fibers | 1~144 | Fiber Type | G652D |
| Fiber Tube | Stainless Steel Tube (SST) | Fiber Gel | Hydrogen absorbing gel |
| Fiber Optic Cable Outer Sheath | LSOH | Armor | Galvanized Steel Wire |
| Inner Sheath | HDPE | Fault location | Copper Tube |
| Interlayer between the armor layers | Asphalt | Outer Sheath | PP Rope and Asphalt |
| Overall Diameter (Nom.) | 24mm (Single Armor)
31mm (Double Armor) 36mm (Triple Armor) |
Weight (In Air) | 1.35 kg/m (Single Armor)
2.96 kg/m (Double Armor) 2.75±0.2 kg/m (Triple Armor) |
| Weight (In Seawater) | 1.02 kg/m (Single Armor)
2.39 kg/m (Double Armor) 2.7±0.2 kg/m (Triple Armor) |
||
| Physical Characteristics | ||||
|
Technical Parameter |
Single Armor Designed Value | Double Armor Designed Value | Triple Armor Designed Value | |
|
Crush(kN) |
15 |
25 |
– | |
|
Ultimate tensile load strength (UTS) Nom. (kN) |
200 |
490 |
– |
|
|
The cable breaking load (CBL) Nom. (kN) |
|
– | – |
510 |
|
The transient tensile strength (NTTS) Nom. (kN) |
160 |
350 |
310 | |
|
The operating tensile strength (NOTS) Nom. (kN) |
120 |
200 |
180 | |
|
Permanent Tensile Load (NPTS) Nom. (kN) |
75 | 150 |
100 |
|
|
Impact(Nm) |
200 |
300 |
– | |
|
Electric resistance(Ω/km) |
≤ 10 | ≤ 10 |
– |
|
|
Insulation resistance(Ω/km) |
≥10 | ≥10 |
– |
|