From the grid to the rack, one partner for data centre infrastructure

Hermesys supplies the physical layer of cloud, AI, HPC and hyperscale data centres: fibre and copper cabling, high-density connectivity, optical transceivers, cabinets and power distribution, cable pathways, power cables, and prefabricated power and IT modules.

10G–1.6TOptical transceivers and interconnects for every network generation
>100 MWof power containers built for colocation operators
Tier I–IVPrefabricated data centre modules designed to Uptime tiers
~9 monthsTypical prefabricated project, from order to ready-for-service

Every layer, from utility feed to server port

Select a product below the drawing, or a point on it, to see where it is used and what it does.

Hermesys data centre infrastructure cutaway Isometric cutaway of a data centre campus showing the utility grid, solar PV, power yard with prefabricated power containers, meet-me room, power room, data hall with cabinets, overhead fibre raceway, cable tray and busway, cooling plant and container data centre, with the Hermesys products used in each area. Meet-Me Room Power Room Data Hall MDA / Core Network Power Yard Utility Grid Solar PV Cooling Plant Container DC Carrier / Metro Network ChimeraX™MV cableChimeraX™RS-485 cableGryphonX™microductChimeraX™LV & DC cablePowercontainerHydraX™optics & DACHydraX™ HDfibre panelLadonX™ribbon cableHydraX™MPO trunkContainerdata centreCetoX™cabinet & PDULadonX™copperCetoX™raceway & tray

Swipe sideways to see the whole site →

Power

ChimeraX™ Medium-Voltage Power Cables

Single-core 15 kV and 22 kV XLPE cables bring the utility medium-voltage supply from the substation to the on-site power modules. Armoured designs are made for direct burial.

  • 15 kV stainless steel tape armoured (SSTA) and 22 kV aluminium wire armoured (AWA) constructions
  • Compact stranded conductor, semi-conductive screens, XLPE insulation and copper tape screen
  • Anti-termite / anti-rodent outer jacket for direct-buried routes
View products

From a single edge cabinet to a megawatt campus

The same product families scale across five deployment models, so cabling, power and pathways stay consistent as a site grows.

01

Micro data centre

Self-contained cabinets with integrated power, cooling and monitoring for branch, factory and edge sites.

02

POD

Rows of cabinets with aisle containment, in-row cooling and overhead pathways, deployed as one repeatable block.

03

Container DC

Pre-built IT modules that add capacity at the edge or beside an existing campus, without a new building.

04

Power container

Prefabricated power trains and skids that grow data hall power in steps, as IT load is added.

05

Traditional DC

Full fit-out of enterprise, colocation and hyperscale buildings, from the meet-me room to every rack.

PrefabricatedAll-in-oneModularSub-systems
SizeISO and wide ISO modules, 20 / 40 / 45 ftSized to the requirementISO and wide ISO modules, skids
ConfigurationAll infrastructure inside one moduleFunctional modules (IT, power, cooling) integrated on siteIndividual sub-systems
CapacityUp to 12 IT racks, hundreds of kWkW to MWMW scale
ResilienceConfigurable to Tier IIIConfigurable to Tier IVPer design
Best forSmall edge data centres with limited footprintSmall to mid-size edge and cloud data centresMid-size to hyperscale data centres

Power containers protecting megawatt colocation sites

A global colocation provider chose Hermesys power containers for its edge network. It needed pay-as-you-go capacity that keeps pace with data centre growth, without giving up reliability or efficiency.

1 platformpower, cooling, monitoring & control
40 ftcustomised power modules
2countries: Australia & Singapore
N+1redundant power train design
Capacity900 / 1,200 kW
Format40 ft module or skid
Efficiency95% online, 91% on generator
UPSModular UPS, AC or AC/DC (inverter + rectifier)
BatteriesVRLA or lithium-ion; 5 min at end of life, longer on request
CoolingChilled-water or DX in-row, DX overhead
Fire systemFM-200 or Novec 1230 clean agent; aspirating smoke detection optional
Power skidUp to 2,400 kW with 10 kV / 380 V 2,500 kVA transformer and 24 × 630 A outputs

Designed, simulated and tested before it ships

Prefabricated modules are built and tested in our factories with a 2.4 MW load bank, a chiller station and 4,000 A switchgear, so on-site work is mostly connection and commissioning.

BIM layout & coordination

3D building information models plan the layout, cable trays, busway and cooling, and are reviewed in section views before anything is built.

CFD airflow analysis

Airflow is simulated for whole data halls, from 3.3 MW halls to high-density deployments of 80 racks at 18 kW each, and for prefabricated power modules.

ETAP power studies

Load-flow, efficiency and short-circuit studies size the breakers and set discrimination before the electrical design is frozen.

Structural testing to ISO 1496-1

Modules pass stacking, transverse and longitudinal rigidity, top and bottom lifting and restraint tests.

Coatings to ISO 12944

Corrosion protection is specified by environment: category C3 for typical sites and C5 for coastal or industrial locations.

Fire & weather protection

Container floors are tested for 2-hour fire integrity to BS 476-21, with sealed joints between modules and sloped roofs to shed rain.

Optional physical hardening

For high-security sites, 4 mm armour steel can be clad inside the container walls, certified to GA 164-2018 grade A.

Tier-trained design team

Engineers trained in Uptime Institute data centre design, operations and specialist programmes.

One team from first survey to after-sales service

Proposal

  • Site survey
  • Conceptual design
  • Technical advice
  • Quotation

Planning & design

  • Layout and system architecture
  • Material selection and BOM
  • Design validation
  • Manufacturing plan

Manufacturing & validation

  • Production management
  • Quality control
  • Level 1 factory witness test
  • Logistics

Installation & commissioning

  • Site management
  • Level 2–4 functional testing
  • Level 5 integrated systems test
  • Client training and handover

After service

  • Warranty and spare parts
  • Repair and troubleshooting
  • Preventive maintenance
  • Service contracts

Civil works and module production run in parallel to shorten the programme; each schedule is confirmed against the project's design and material status.